Filter Results By:

Products

Applications

Manufacturers

Showing results: 1096 - 1110 of 1142 items found.

  • Thermocouples

    WIKA Alexander Wiegand SE & Co. KG

    Thermocouples are temperature sensors that generate a voltage directly dependent on temperature. Compared to resistance thermometers, they are particularly suited for high temperatures up to 1,700 °C. Instrument designs from mineral-insulated sheathed cable are very resistant against extremely high vibration loads (depending on instrument model, sensor element and wetted materials). The accuracy classes 1 and 2 apply for thermocouples in accordance with IEC 60584 as well as the standard and special classes in accordance with ASTM E230.

  • Hotsale Withstanding High Voltage And Insulation Resistance Tester

    RK7112 - Shenzhen Chuangxin Instruments Co., Ltd.

    The tester is applied to the home appliances, computer peripheral equipment, electric products, communication products, lighting products, small home appliance products, lighting equipment, electronic components, transformers, motors, compressors, electric heat pipe, wire, cable and high voltage safety system’s withstand voltage and leakage current test, as well as it’s an indispensable dielectric

  • VLF Testing and Diagnostics System

    PHG 70 TD/PD - BAUR Prüf- und Messtechnik GmbH

    Cable testing and diagnostics with the BAUR PHG 70 TD/PD. With the PHG TD/PD, you get a multifunctional cable testing and diagnostics system that was specially designed and developed for medium-voltage networks. The PHG TD/PD system is also the only cable testing and diagnostics system that gives a comprehensive overview of the quality and ageing condition of the test sample. The diagnostic methods TD and PD are mutually complementary, because on one hand you can detect the complete condition and on the other hand locate * individual faults in the operating resources.* High performance VLF truesinus testing device (3 kW) with regulated output voltageCompact, enclosed design in 19" format* Variable installation option with separate control and voltage unit* Variable connection options to cable stations of different models

  • Hi Pot Meters

    Bierer & Associates, Inc

    The HI Pot Device is designed to Hi Pot de-energized 15kV class cables. The tool transforms 18 Volts from the battery to approximately 8,000 volts DC. When the battery is installed and the safety switch is in the closed down position, the unit is in voltage detection mode. The unit should be in this position when installing the device, as it will sound a warning alarm if you approach an energized source. When the safety switch is lifted and the toggle switch is switched up, the unit is in the Hi-Pot mode and the high voltage DC is being applied.

  • 2100Vdc Screw Terminal Connector Board | Cable & Harness Tester

    CB29H - CAMI Research Inc. (CableEye®)

    CAMI Research Inc. (Acton, MA) announces another new board for its CableEye cable and harness testing systems. Populated with four 16-pole screw terminal blocks, the board addresses high voltage (HiPot) testing to 2100Vdc/1200Vac. Of particular interest to the harness testing market, the CB29H is also available as a transition board variant (CB29AH). The CB29H and CB29AH boards are high voltage versions of the CB29 with the high voltage traces running on inner layers to afford additional safety, and protection from contamination. Each contains four 16-pole screw terminal blocks that will accept bare wires from 12- to 30-gauge in size. The metal jaws firmly grip an inserted wire without damaging or distorting the end, and the space between each terminal block may be used as a wire channel to guide wires neatly to the side. For each channel, a pair of holes is provided through which wire ties may be inserted to hold the wire bundles in place.

  • HV Amplifier

    Model 20/20C - TREK, INC.

    The Model 20/20C is a DC-stable, high-voltage power amplifier used in industrial and research applications such as electrostatic deflection, electrophoresis research, dielectric studies, and accelerated life-testing of high tension cables for power transmission. The Model 20/20C provides precise control of output voltages in the range of 0 to 20 kV DC or peak AC with an output current range of 0 to 20 mA DC or peak AC.

  • UHF PD Detector

    Megger Group Ltd.

    Handheld online PD substation surveying system. The UHF PD Detector is the ideal tool for quick, non-invasive surveys in MV and HV substations and should be part of the toolkit for all maintenance and service teams. Due to its high measurement bandwidth, the UHF method provides accurate local online partial discharge (PD) measurements on HV components such as cable end-terminations, surge arrestors, voltage transformers and isolators.

  • HV AC Voltage Test Systems

    Fivestar HV Testing Equipment Co., Ltd.

    FSHV offers three different types of AC voltage test systems, the conventional type is AC test transformer design, mainly for testing objects of medium & low capacitance products, particularly for tests requiring stable voltage even if the load changes under voltage (corona, wet & pollution tests) or when the load is inductive (like inductive voltage transformers). Another is AC resonant test systems, according to series resonance circuit XL=XC (2πfL=1/2πfC), by setting F frequency of power supply or L inductance of reactor, generate a pure sinusoidal waveform of the test voltage, and the required input power is only 1/Q. Variable frequency type operates in a frequency range from 20Hz to 300Hz, ideal for field commissioning test of power cables and GIS/GIL. Variable inductance type outputs continuous AC voltage of power frequency (50/60Hz), mainly for factory testing of high and ultra-high voltage cables, power transformers, GIS, etc.

  • AC Resonant Test System

    Yangzhou Power Electric Co., Ltd

    Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.

  • High Frequency Current Transformer

    HFCT Ø 140mm - Techimp HQ S.r.L

    Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).

  • Coaxial Switch, DC to 4 GHz, SPDT, 75 Ohms

    8762F - Keysight Technologies

    The Keysight 8762F brings a new standard of performance to 75-ohm coaxial components. Designed for ATE switching systems, the Keysight 8762F offers the performance demanded by the cable television distribution equipment and communications equipment industries. It gives the ATE system designer of telecommunications and cable distribution equipment the tools to design reliable, high performance switching interfaces. The Keysight 8762F uses a mini 75-ohm SMB connector for the coaxial interface. The mini 75-ohm SMB connector is designed to terminate RG-179 75-ohm coaxial cable. The Keysight 8762F is designed to work in virtually any system due to the range of voltage options covering 4.5 V to 30 Vdc available for activating the switch solenoids. The standard configuration of the switch includes solder terminals.

  • Digital Insulation Testers

    The Motwane Manufacturing Company

    Motwane is India’s first company to design and develop an intelligent digital insulation tester that conducts insulation resistance tests on high voltage electrical equipment. Products like transformers, generators, motor cables, bushings, LAs, and switchgear, are prone to gradual degradation over time due to the adverse effects of temperature, humidity, and dust. The gathered test data allows clients to verify the current quality of insulation, and take appropriate action.

  • Partial Discharge Measuring System

    LDS-6 - Doble Engineering

    The Doble LDS-6 is a highly sophisticated digital measuring system for partial discharge detection and analysis. It is trusted as a valuable tool for factory and laboratory testing.The LDS-6 can be used to test a variety of high voltage apparatus. Use the LDS-6 to perform PD quality tests on motors, generators, transformers, MV and HV cable systems, switchgear and additional HV accessories.The LDS-6 complies with IEC 60270, VDE 0434 as well as various IEEE and other standards.

  • PXI 8x SPST High Voltage Reed Relays

    40-310-001 - Pickering Interfaces Ltd.

    The 40-310/320 range of high voltage switching modules will hot switch up to 750V peak and cold switch up to 1000V peak in either general purpose relay (40-310) or multiplexer (40-320) configurations. These modules contain high-quality reed relays with switching ratings comfortably higher than the 40-310/320 specification. Applications include; circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing.

  • Wind Direction Sensor

    ENVIROMUX-EWDS - Network Technologies Inc

    Balanced wind direction vane with a near-zero friction bearing and a high accuracy magnetic angle sensor to provide precision wind direction. Sensor range: full 360 degrees , zero deadband. Accuracy: ±1.8 degrees. Resolution: 12 bit or 0.025 degrees. Directional Vane approximately 8 inches (203 millimeters). 3 wire flying leads, 25-feet (7.6-meter). Supply voltage: 4.5 to 5.5 VDC. Current: 15 mA typical. Output: 5 to 95% of input voltage (0.25 to 4.75VDC). Requires the ENVIROMUX-S5VDC-5V to operate with ENVIROMUX-2D/5D/16D. Maximum cable length: 1000 ft (305m)

Get Help